2019 QUINTUS QIH-48 M URQ
Hot Isostatic PressPressure vessel
Max. operating pressure: 207 MPa
Design pressure: 228 MPa
Pressure vessel volume: 435 dm³
Total weight of complete unit, approximately: 24 000 kg
Operability
The pressure vessel is designed to operate: 0-24 hrs/day
Control system
Programmable controller (PLC): Rockwell Allen-Bradley
ControlLogix system
Supervisory System – HMI system: PC based with System
Platform(InTouch) from
Wonderware
Remote access: eWon
Backup Power (UPS) time, of control system, at power failure: > 20 min
Gas compressor system
Number of compressor(s): 2 pcs
Maximum compressor pressure: 207 MPa
Vacuum system
Number of pump(s): 1 pcs
Vacuum pressure level less than: 5 mbar
Cooling system
Number of pump(s): 1 pcs
Type of pump for emergency cooling: Gas-driven
Maximum outdoor Wet-bulb temperature: 22 °C
Site utilities
Electric power
Supply voltage, 3 phase: 400 / 480 V
Maximum voltage variation: ± 5 %
Frequency: 50 / 60 Hz
Totally installed power, approximately: 300 kVA